当前位置: 中文主页 >> 研究成果 >> 论文成果
论文成果

Leakage characteristic of helical groove seal designed in reactor coolant pump

发表时间:2019-03-11
点击次数:
论文类型:
期刊论文
第一作者:
Zhang M.
通讯作者:
Zhang, M.; School of Energy and Power Engineering, Dalian University of Technology, No. 2, Linggong Road, Liaoning, Dalian 116024, China; email: zmdlut@qq.com
合写作者:
Wang X.-F.,Xu S.-L.,Yin S.
发表时间:
2012-01-01
发表刊物:
International Journal of Rotating Machinery
收录刊物:
EI、Scopus
文献类型:
J
卷号:
2012
ISSN号:
1023621X
摘要:
Helical groove seal is designed in reactor coolant pump to control the leakage along the front surface of the impeller face due to its higher resistance than the circumferentially grooved seal. The flow and the friction factors in helical groove seals are predicted by employing a commercial CFD code, FLUENT. The friction factors of the helical groove seals with helix angles varying from 20 deg to 50 deg, at a range of rotational speed and axial Reynolds number, were, respectively, calculated. For the helically grooved stator with the helix angle greater than 20 deg, the leakage shows an upward trend with the helix angle. The circumferentially grooved stator has a lower resistance to leakage than the 20 deg and 30 deg stators. It can be predicated that, for a bigger helix angle, the friction factor increases slightly with an increase in high axial Reynolds number, which arises from the high-pressure operation condition, and the friction factor is generally sensitive to changes in the helix angle in this operation condition. The study lays the theoretical foundation for liquid seal design of reactor coolant pump and future experimental study to account for the high-pressure condition affecting the leakage characteristic. ? 2012 Meng Zhang et al.
是否译文:

辽ICP备05001357号  地址:中国·辽宁省大连市甘井子区凌工路2号 邮编:116024 版权所有:大连理工大学


访问量:    最后更新时间:..